STANDARD EQUIPMENT:
20 HP Motor, Pump & Filter Modulationg Inlet Valve
800 Gal Tanks (1 300 & 1 500) Magnetic Motor Starter
Positive Lubrication Fluid Pump Spin on Fluid Filter
Standard NEMA Motor, 3-Phase, 60hz, 230/460-volt Air-Cooled or Water-Cooled
Temperature Regulating Valve Fluid Level Sight Glass
Fluid Filter Pressure Indicator Synthetic Fluid
ACCESSORIES:
Inlet Filters (Std. QSVI 25, 40, 50) Vaccuum Gauges
Vaccuum Ball Valves Vaccuum Check Valves
Exhaust Demisters
PROTECTION DEVICES:
Pressure Relief Valve
High Discharge Temperature Shutdown System w/Manual Reset
APPLICATIONS:
Medical/Dental Printing & Paper Rubber & Plastics
Material Handling Food Processing Meat Packing
Electronics R & D Systems Grinding multi units.
THE SECTION OF A LARGE PLANT WAS CLOSED BECAUSE OF AN ENGINEERING CHANGE IN
THE PRODUCT- THE PLANT MANAGER CLAIMED THE COOLANT SYSTEM SAVED THEM ABOUT
100,000.00 DOLLARS A YEAR, IT SHOULD LAST ANOTHER 30 YEARS.
SPECIFICATIONS:
Drive Motor ............................. 20 HP
Drive System Belt ....................... Belt
Inlet Capacity .......................... 319 ACFM
Max. Operating Pressure (Continuous) .... 10" HgV (506 torr)
Min. Operating Pressure (Continuous) .... 29.9" HgV (.5 torr)
Base Pressure ........................... 29.9" HgV (.5 torr)
Maximum Ambient Temperature ............. 110 Degrees F
Minimum Ambient Temperature ............. 32 Degrees F
Inlet Connection ........................ 3" NPT
Discharge Connection .................... 2" NPT
Rotor Diameter .......................... 127.5mm
Rotor Length ............................ 217mm
Rotor Speed - Male ...................... 5,800 RPM
Rotor Speed - Female .................... 3,867 RPM
Tip Speed ............................... 38.7 meters/sec.
Maximum Safe Speed ...................... 7,500 RPM
Intake Male Bearings .................... Cylindrical Roller Bearings (x1)
Discharge Male Bearings ................. Tapered Roller Bearings (x2)
Intake Female Bearings .................. Cylindrical Roller Bearings (x1)
Discharge Female Bearings ............... Tapered Roller Bearings (x2)
Displacement at Operating Speed ......... 350 CFM
Volumeteric Efficiency .................. 91.1%
ELECTRICAL DATA:
Full Load Package BHP (Air Cooled) ...... 19.8 BHP
Package Electrical Consumption-Air ...... 16.7 KW
Full Load Package BHP (Water Cooled) .... 19.0 BHP
Package Electrical Consumption - Water .. 16.0 KW
Drive Motor Service Factor .............. 1.15
Drive Motor Speed (Nominal) ............. 3,600 RPM
Specific Power Air Cooled ............... 6.2 BHP/100
Specific Power Water Cooled ............. 6.0 BHP/100
Typical Standard Motor Efficiency ....... 88.5%
Typical High Efficiency Motor ........... 89.5%
Typical Premium Efficiency Motor ........ 92.4%
LUBRICATION:
Method of Lubrication ................... Pump
AIR COOLED DATA:
Max. Heat Rejection ..................... 546 BTU/min.
Cooling Fan Static Pressure ............. 0.3" wc
Fan RPM ................................. 3,600
Fan Flow ................................ 2,240 CFM
WATER COOLED DATA:
Water Flow - 50 Degree F ................ 2.8 gal/min
Water Flow - 70 Degree F ................ 3.3 gal/min
Water Flow - 90 Degree F ................ 4.0 gal/min
Maximum Water Delta T @ 50 Degree F ..... 23.3 Degrees F
Recommended Water Pressure .............. 100 psig
Typical Water Cooler Pressure Drop ...... 7 psi
Water Connections ....................... 1/2" NPT
MAXIMUM DIMENSIONS:
Length .................................. 65"
Width ................................... 34"
Height .................................. 46"
Weight .................................. 980 Lbs.
F.O.B. Truck, Location